Switchgear Technicians in Georgia can Detect Dependability Inhibiting Generator Component Malfunctions

Switchgear is a general term used to describe the breakers and disconnects used to control current flow in your backup generator. A technician needs to test these electrical components regularly to ensure they are capable of handling possible shorts or overloads. Prime Power, based in Georgia, is ready to meet all of your installation, maintenance, and servicing needs. Our switchgear technicians in the Georgia area are current with all National Electric Code guidelines as well as the individual maintenance needs of your generator.

Switchgear testing should be an active part of secondary power system maintenance. You can have one of our experienced technicians make a special visit to ensure these components are up to par, or simply schedule a routine servicing appointment for a full system evaluation. We take pride in the expert knowledge our technicians possess and have many years of experience to back all services offered. You can receive a dependable generator maintenance routing by having an inspection and testing completed by one of our professionals.

Breaker Testing Georgia: What is a Technician Looking for during Servicing?

Higher voltage switchgear for the operation of large electronic machines became available in the late nineteenth century. Switchgear is designed to break current when a fault takes place. Multiple components can perform this process; however, the circuit breakers are most common when discussing an emergency or backup power source. These components may be insulated by air, gas, oil, or vacuum methods. Breakers are the main facilitator for current interruption, but are supported by many additional components. The two contacts on a breaker remain closed until a fault is detected, thus supporting the arc necessary for current flow.

A circuit becomes disconnected when the contacts are pulled apart into an open position. Designs may use a magnetic field, vaporization, or compressed air to complete contact separation. They can extinguish current flow in a matter of seconds when cared for appropriately. If internal components of the breaker malfunction, the continued current flow could cause safety risks and damage. Breaker testing by Georgia professionals decreases the risk of continued flow as well as startup failure.

Circuit breakers are mechanical components that could deteriorate over time for several reasons. Environmental contamination, usage wear, and corrosion could lead to the switchgear not opening upon the occurrence of a fault. Breaker testing by a Georgia servicing company verifies these components are in the proper condition for operation and will perform as expected if a situation arises. The timing delay could be altered from these factors even if mechanical functionality is correct. This issue leaves devices open for damage and could open circuits in the wrong location.

All switchgear will be thoroughly tested by the manufacturer, but could leave the factory defective or naturally deteriorate as time passes. While these devices are not normally tested under full power at the location, low voltage evaluations can be used to determine if delays and operations will be dependable during usage. A visual inspection, in combination with testing by a professional switchgear technician in Georgia can often pinpoint any large issues regarding each individual breaker.